Polypropylene lined composite hose with galvanized steel inner and outer wires with 100% aromatic resistant barrier layers embedded in the hose wall to prevent permeation and leakage.
Hose assemblies are conductive and are capable of full vacuum with a diverse selection of end fittings for hydrocarbon transfer applications. Working pressures of up to 250 psi (17 bar) with conformance to EN 13765:2010 and working temperatures of up to 100 degrees C (212 F).
Oilmaster® Polypropylene Hydrocarbon Hose Type GGP901
This type is specially designed for the robust transfer of all lube oils, petrol, diesel (solar) and distillates.
Color/Cover: Black with a Blue Stripe/PVC Coated Nylon, Abrasion, UV and Ozone Resistant
Inner Wire: Galvanized Steel
Inner Lining: High Density Polypropylene
Carcass: Polypropylene Fabrics, Films
Outer Wire: Galvanized Steel
Extra: Special Color Coding and Branding
Temperature Range: -22°F to +212°F (-30°C to +100°C)
Maximum Elongation: ≤10% on test pressure
Vacuum Range: 26 inHg (660 mmHg), 0.9 bar
Electrical Properties: Electrically Conductive; ≤2.5 ohm/m for sizes less than 2″; ≤1.0 ohm/m for size 2″ and above
BS5842, NAHAD -60 0:2005
Specially designed end fittings have been developed for use with Titeflex US Hose composite hoses that have a unique leak-proof sealing face and specially machined helical spiral shank which engages into the corresponding internal helix wire when secured into the hose by either crimping or swaging the external ferrules.
Pressure based on safety factor 4:1. Dimensions and weight are approximate and are subject to change. For additional technical data such as pressure drop, max. flow rates and tensile strength, please consult Titeflex US Hose engineering. Increased operating temperatures will reduce working pressure of the assemblies. Fitting pressure rating may limit working pressure of the assembly. Rated working pressure is @ 70°F (21°C).