Polypropylene lined composite hose with a high tensile strength galvanized steel inner and outer wire.
Specifically engineered with 100% petroleum resistant barrier layers embedded in the hose wall to prevent permeation and leakage during bottom loading applications. Available in sizes 3” and 4” diameter, hose assemblies are conductive and capable of pressure up to 200 psi (14 bar) or full vacuum. A diverse selection of end fittings is available for hydrocarbon transfer applications.
Rackmaster™ Composite Hose Bottom Loading Hose Type 1061GGP
This type is designed exclusively for the bottom loading arm application for filling tank trucks suitable for all grades and blends of refined gasoline products with unique fiberglass flame resistant layer.
Color/Cover: Black/PVC coated Nylon, Abrasion, UV and Ozone Resistant
Inner Wire: Galvanized Steel
Inner Lining: High Grade Polypropylene
Carcass: Fiberglass Flame-Resistant Layer, Polypropylene Fabrics, Films and Seamless Tubes
Outer Wire: Galvanized Steel
Logo: Rackmaster™
Temperature Range: -22°F to +212°F (-30°C to +100°C)
Maximum Elongation: ≤10% on test pressure
Vacuum Range: 26 inHg (660 mmHg), 0.9 bar
Electrical Properties: Electrically Conductive; ≤1.0 ohm/m
EN13765:2010, Type 3, IMO, IBC, BS5842, NAHAD-600:2005
Specially designed end fittings have been developed for use with Willcox Composite hoses that have a unique leak-proof sealing face and specially machined helical spiral shank which engages into the corresponding internal helix wire when secured into the hose by either crimping or swaging the external ferrules.
For l061GGP RackMaster Bottom Loading Hose measure the lengths as either “pressurized” or “empty”. The effect of elongation must be calculated in order to produce the correctly manufactured length and price.
Pressure based on safety factor 4:1. Dimensions and weight are approximate and are subject to change. For additional technical data such as pressure drop, max. flow rates and tensile strength, please consult Titeflex US Hose engineering. Increased operating temperatures will reduce working pressure of the assemblies. Fitting pressure rating may limit working pressure of the assembly. Rated working pressure is @ 70°F (21°C).